The KIDE Cryogenic Platform is designed for large-scale quantum computing, and supports more than 1000 qubits.

The KIDE Cryogenic Platform is a cryogenic measurement system designed for large-scale quantum computing. It can support the measurement infrastructure required to operate over 1000 qubits, with a capacity of over 4 000 RF lines and 500 kg of payload.

The system brings unparalleled user access, with doors on the self-supporting vacuum chamber enabling the system to be operated by a single person. It also offers users enhanced control of the cryogenic technology through separated cooling, enabling user-specific configurations. 

Product Highlights


1.0

KIDE Cryogenic Platform

Large-Scale Cryogenic Measurement System


Built for Large Quantum Computing Infrastructure 

The KIDE Cryogenic Platform is designed for the needs of large-scale quantum computing. The system features a large payload space via the 1.6 m2 surface area of the base temperature flange. This large area is complemented by the ability to support a heavy mass of up to 500 kg.

The system has three cooling units, providing an expected > 3000 µW of cooling power at 100 mK. With its large payload space and cooling power, the KIDE Cryogenic Platform supports the measurement infrastructure needed for operating over 1000 qubits. 


Vast Wiring Capabilities 

The KIDE Cryogenic Platform provides vast wiring capabilities with over 40 available ports, including 24 line-of-sight side-loading ports. This allows for more than 4000 High-Density Wiring RF lines to be installed into the system. 

  • 24 LOS side-loading ports 
  • 12 side ports (non-LOS) 
  • 9 x KF40 ports 

Easily Accessible Payload Space 

User access to cryogenic measurement systems has been reimagined and redesigned with the KIDE Cryogenic Platform. The system features a self-supporting vacuum chamber and radiation shields, with direct access to the payload space available through the full height doors on the vacuum chamber. This provides easy access to user payloads and installed measurement infrastructure, making it easy for one person to operate and maintain the system.  


Better Control with Separated Cooling

The system enables better control of the cryogenic technology through separated cooling. Three independent dilution cooling units can be used to optimize payload cooling through multiple cooling configurations. The system also offers a high cooling capacity above 4 K provided by 9 Pulse Tube Cryocoolers with functional separation. There are dedicated pulse tubes for operational cooling, customer payload cooling, and cooling the shields.

These features deliver improved control of the technology and allow for user-specific configurations of available space, cooling power, and temperature.  


Long Cooling Cycles 

The KIDE Cryogenic Platform can be run with extended cooling cycles, providing the optimal environment to operate quantum computers for long periods of time without interruption. The system features a Long-Life Cold Trap that allows continuous operation of the system for up to three years when used together with the LN2 Trap.


Ease of Maintenance 

The cooling units of the system are loaded from the top of the system, which enables them to be serviced with minimum affect on the user wiring and components. The self-supporting vacuum chamber with multiple access points also enables easier maintenance of the system.

System internals can be easily accessed using the doors, and the radiation shields of the system have frames with detachable side walls and bottoms, which can be removed by one person.

The large size of the system also makes it possible to work inside the system at the base stage. 


Services

Total System Care

Total System Care enables you to focus on your own work – doing research and measurements. The service ensures that systems operate at the best possible performance level and with maximal uptime, without users needing to spend time maintaining the systems themselves.

Technical Specifications


2.0

KIDE Cryogenic Platform

Large-scale Cryogenic Measurement System

Note: Cooling power is measured from the KIDE insert flange. 

KIDE Cryogenic PlatformTypical
Base temperature 10 mK
Cooling power at 20 mK divided to 3 sections>90 μW
Cooling power at 100 mK divided to 3 sections>3000 μW
Base Temperature Flange Size 1.6 m2 
Wiring Capacity >4000 RF lines 
Maximum Payload Weight 500 kg 

Services

Customer Care

We support our customers throughout the lifetime of their system, providing dedicated care to find solutions for any issues. Our technicians and engineers are ready to help you wherever you are located, with prompt service delivered either remotely or on-site.

Layout and Facility Requirements


3.0

KIDE Cryogenic Platform

Large-scale Cryogenic Measurement System


Layout

Each Bluefors system is designed to be installed at a specific location defined in advance. A separate layout drawing is made for each system, and should always be referred to for exact dimensions. 

Facility Requirements

The basic requirements for our systems are 3-phase electricity, cooling water, and compressed air. The full list of requirements and specification details can be found in the Pre-Installation Guide. Please contact our sales team for a copy. 

Get in touch with us.

Contact form – choose your product or service interest:


Name(Required)

Your personal data will be processed in accordance with our Privacy Notice.

This field is for validation purposes and should be left unchanged.
Name(Required)

Your personal data will be processed in accordance with our Privacy Notice.

This field is for validation purposes and should be left unchanged.
Name(Required)
Address

Your personal data will be processed in accordance with our Privacy Notice.

This field is for validation purposes and should be left unchanged.
Name(Required)
Address

Your personal data will be processed in accordance with our Privacy Notice.

This field is for validation purposes and should be left unchanged.
Name(Required)

Your personal data will be processed in accordance with our Privacy Notice.

This field is for validation purposes and should be left unchanged.
Name(Required)

Your personal data will be processed in accordance with our Privacy Notice.

This field is for validation purposes and should be left unchanged.